iDP-3420/3421/3423 User’s Manual

ESC "¤" n "data" CR or LF

[Function]

Defining the message

[Code]

<1B>H <2F>H n "data" CR or LF

[Range]

1 £ n £ 10

[Outline]

This command can define up to a 50-byte message in one line. If the value of n

 

is specified beyond the range, the data following n will be treated as the print

 

data.

 

Once the message is defined, it remains valid until it is redefined. The data

 

should end with CR (0DH) or LF (0AH). If the data exceeds 50 bytes, the

 

subsequent data will be treated as the print data.

 

Once the message is defined, it remains valid until it is redefined or the download

 

deletion command (ESC DC2 n1 n2) is executed.

ESC "DC3" n

[Function]

Printing the message

[Code]

<1B>H <13>H n

[Range]

1 £ n £ 10

[Function]

This command prints a message. If the value of n is specified beyond the range,

 

the message will not be printed.

101

CITIZEN

Page 101
Image 101
Citizen Systems iDP-3423, iDP-3420, iDP-3421 user manual ESC ¤ n data CR or LF