ESC "p" m n1 n2

[Function]

Specifying the pulse generation

[Code]

<1B>H <70>H m n1 n2

[Range]

0 £ m £ 1

 

 

 

0 £ n1 £ n2 £ 255

[Outline]

This command outputs the signals specified with n1 and n2 to the connector pins.

 

 

 

 

 

 

 

m

 

Connector Pin

 

 

 

0

 

Drawer kick connector No. 2 pin

 

 

 

1

 

Drawer kick connector No. 5 pin

 

 

The ON time is n1´2 mS and the OFF time is n2´2 mS.

[Caution]

The user should consider driving the drawer at the following duty ratio.

 

 

ON time ¸ (ON time + OFF time) £ 0.2

 

 

(It is recommended to make n2 four times higher or more than n1.)

The drawer kick-out solenoid should have a resistance value of 36W or more. Do not use a lower one because an overcurrent will flow. For the drawer power, be sure to use the printer power (Drawer kick-out connector No. 4 pin).