ESC D [ n ] k NUL

[Function]

Setting Horizontal Tab Position

[Code]

<1B>H<44>H [ <n> ] k<00>H

[Range]

{0 =< n =< FF(Hex)}

 

{0 =< k =< 20(Hex)}

[Outline]

Specifying a horizontal tab position.

 

¥ ÒnÓ indicates the no. of columns from the beginning to the horizontal tab position.

 

At this time, n= set position Ð 1 is to be specified. For example, to set the position

 

at 9th column, n=8 is to be specified.

 

¥ k denotes the number of horizontal tab positions you want to set.

 

¥ The tab position is set at position where it is Òcharacter width ⋅ nÓ from the line

 

beginning. The character width, at this time, includes the rightward space amount.

 

In double wide characters, it is made double of the ordinary case.

 

¥ Tab positions can be specified are maximum 32. Specifying exceeding this is

 

ignored. <n> k, which denotes a setting position, is input in the increasing order

 

and ends at <00> H.

 

¥ ESC D NUL clears all the set tab positions. Following clearing, horizontal tab

 

command is ignored.

[Caution]

When the data, <n> k, is equal to or smaller than its preceding data, <n> k-1, it is

 

assumed that tab setting is finished. If this is the case, the next data onward will be

 

processed as normal data. When the data, <n> k, exceeds a 1-line print area, set the

 

horizontal tab position, assuming ÒSet digit position = Maximum print digits + 1.Ó

 

The horizontal tab position does not change even if the character width is altered

 

after setting the horizontal tab position.

[Default]

Initial value is specified every eight characters (9th, 17th, 25th, and on) of Font A.

[See Also]

HT

[Sample Program]

 

[Print Results]

See Sample Program and Print Results for HT.

Ñ 24 Ñ

Page 26
Image 26