10. AC ADAPTOR
| (1) | Input voltage | 100V ~ 240V AC (50/60 Hz) | 
| (2) | Input current | 250 mA | 
| (3) | Rated output | 9V ±5% | 
| (4) | Efficiency | 65% or more (AC 100V/50 Hz full load) | 
| 
 | 
 | 70% or more (AC 240V/50 Hz full load) | 
| (5) | Ripple and noise voltage | Less than 150  | 
| (6) | Insulation test | More than 100M ohm | 
| 
 | 
 | (DC 500V, 1 minute, between primary and secondary circuit and chassis) | 
| (7) | Leakage current | 0.25 mA or less (AC 240V/50 Hz) | 
| (8) | Temperature rise | 45K or less on case surface (100 VAC/50 Hz full load @25¡C) | 
| (9) | Over voltage protection | 120% - 150% | 
| (10) | Overload protection current | 1.8 - 3.5A (AC  | 
| (11) | No load power consumption | 3W or less (AC 240V, 25¡C) | 
| (12) | Safety standard | UL,  | 
| 
 | 
 | VDE, GS, CE  | 
| (13) | Size | |
| (14) | Case material | |
| (15) | Cable | 1828.8 mm UL2468#22 ⋅ 2C | 
| (16) | Plug | 3.5 ⋅ 1.3 ⋅ 9.5S | 
| (17) | Polarity | Center Ó+Ó | 
| (18) | Weight | 104 g ±5g | 
11. EMI STANDARD
VCCI Class B
FCC Class B
EN55022
Ñ 78 Ñ