Programming

System Initialization and Default Reset

Following this procedure will set all System Programming Parameters to factory default settings.

1.Turn on ignition.

2.After 4 seconds, press and hold Buttons 1 and 2 together for 5 seconds.

The siren will emit one long chirp, indicating that the reset signal was received.

3.Turn ignition off.

All System Programming parameters are now set to factory default settings.

The Arming Mode is set to Remote Arming only.

The Valet Mode is off.

The Logic Sensor II shock sensitivity is set to Level 6.

The Logic Sensor II motion sensitivity is set to Level 4.

Arming Mode Selection (Passive or Active Arming)

Using the Remote Transmitter, you may select Passive Arming with chirp confirmation, Passive Arming without chirp confirmation, or Active Arming (Remote only).

To set the Arming Mode:

1.Turn the ignition on.

2.Within 4 seconds, press Transmitter Buttons 1 and 2 together.

First push:

one chirp

=

Passive Arming with chirp

Second push:

two chirps

=

Active Arming

Third push:

three chirps

=

Passive without chirp

3. Turn off the ignition key to save your selection.

Entering System Programming

To enter System Programming:

1.Turn the ignition on.

2.Within 4 seconds, press Transmitter Button 2.

The siren will emit one short chirp, indicating that you have entered Programming Step 1.

The status LED will show the current setting of Step 1 (solid or flashing).

3.You can now make changes to the Programmable System Parameters.

Press Button 1 to change the setting.

Press Button 2 to move to the next step.

4.When you are finished, turn the ignition key off to save your changes. You can turn the key off at any time during programming. When the key is turned off, the changes that you have made will be saved.

MS8200 / MS8300 Installation Manual - Page 17