Programmable System Parameters
Status LED
2 Button
Step
1
2
3
4
5
6
7
8
9
10
11
Function
Ignition Controlled Door Locking
Logic Sensor II Warn Away Level
Logic Sensor II Defeat by Remote
Audible Tamper Alert report
Door Unlock Pulse
Siren Duration - Instant Triggers (door, hood, trunk, ignition)
Siren Duration - Sensors (Logic Sensor II, optional sensor)
Radar Sensor Warn Away Trigger
Full Time System Diagnostic Delay Auxiliary Function 2 output
Auxiliary Function 3 output
Button 1
|
|
| flashing |
| flashing | ||
solid* |
| (quickly) |
| (slowly) | |||
ON |
|
| OFF |
|
|
|
|
High |
|
| Low |
|
|
|
|
ON |
|
| OFF |
|
|
|
|
audible |
|
| LED only |
|
|
|
|
single pulse |
|
| double pulse |
|
|
|
|
40 seconds |
| 20 seconds |
|
|
|
| |
|
|
|
|
|
|
| |
20 seconds |
|
| 40 seconds |
|
|
|
|
|
|
|
|
|
|
| |
warn only |
|
| trigger |
|
|
|
|
20 seconds |
|
| no delay |
|
|
|
|
momentary |
|
| latched |
|
| 30 seconds |
|
momentary |
|
| latched |
|
| 30 seconds |
|
|
|
|
|
|
|
|
|
* default setting
1.Ignition Controlled Door Locking / Unlocking. Selects whether or not the system automatically locks the doors when the ignition is turned on. When selected, the Ignition Controlled Door Locking feature will automatically lock the doors 10 seconds after the ignition key is turned on and automatically unlock the doors when the ignition key is turned off.
To prevent the keys from being locked inside the vehicle when Ignition Controlled Door Locking is on:
•The system will not lock the doors if any door is open when the ignition is turned on.
•The system will not lock the doors if any door is opened during the 10 second countdown.
2.Logic Sensor II - Warn Away Level. Allows you to set the level of the Logic Sensor II’s Warn Away sensitivity. When High is selected, a lighter impact will produce a warning chirp, while the Low setting requires a stronger impact.
3.Logic Sensor II Defeat by Remote. When selected, this feature will allow the user to temporarily disable the Logic Sensor II using the Remote Transmitter.
To turn off the Logic Sensor II by remote:
1.Press the Mode button 3 times, holding it down on the third press.
•The LED on the Transmitter will glow red.
2.Continue holding the Mode Button.
Page 18 - MS8200 / MS8300 Installation Manual