The sensitivity of the Logic Sensor II’s Light Impact Response can also be adjusted. There are two settings for Warn Away, High and Low. The default setting is High. To change the setting, see Programming.
Space Shield III
The Space Shield III is a dual zone proximity sensor that uses high frequency radar signals to detect the presence of moving objects within a defined area. For more information, see Mounting Components.
OperationWhile the system is armed, each time the Space Shield III detects movement in the Exterior zone, the siren will emit a warning chirp. When movement is detected in the Interior zone, the system will trigger.
The Space Shield III can be set to operate in one of two ways: with and without Perimeter Alarm. To select the Operating Mode of the Space Shield III, see Programming - Step 8, Radar Sensor Warn Away Trigger.
With Perimeter AlarmWhen movement is detected in the Exterior zone 3 times, within 15 seconds, the system will trigger.
Without Perimeter AlarmDetected movement in the Exterior zone will cause the siren to emit a warning chirp. Only movement in the Interior zone will trigger the system.
Adjustment
To Enter Space Shield III Adjustment,
1.Turn on the ignition.
2.Within 4 seconds, press the Mode Button twice, then Button 1.
•The siren will emit one chirp.
•The radar sensor will turn on and perform a system check. (This will take approximately 15 seconds.)
•When the sensor is ready, the siren will chirp 3 times and the Interior zone can be adjusted.
3.Test the Interior zone sensitivity.
•Each time the sensor detects movement, the siren will chirp 1 time and the LED on the sensor will light red.
4.To make adjustments:
Press Button 1 to increase the sensitivity.
Press Button 2 to decrease the sensitivity.
•The siren will emit one long chirp when the sensitivity is increased and two long chirps when the sensitivity is decreased.
Page 22 - MS8200 / MS8300 Installation Manual