ClearOne comm AP800 Mute, Explanation, Return Values, Appendices ~ Appendix F Serial Commands

Models: AP800

1 68
Download 68 pages 59.79 Kb
Page 56
Image 56
MUTE

52

MUTE

This command changes or reports the state of mute for a given channel.

[DEVICE] MUTE <CH> <W> <X>

Explanation

<CH>

CH= 1-8 Parameter to apply to the specified microphone channel

CH= A-D Parameter to apply to select the line channel CH= 1-2 Parameter to apply to select the subbus channel CH= * Parameter to apply to all microphone channels

<W>

W=S Parameter to set subbus

W=I Parameter to set input

W=O Parameter to set output

<X>

X=0 Set mute to OFF

X=1 Set mute to ON (mute the selected channel)

X=2 Parameter to toggle the state from one state to the other (regardless of current state)

X=NULL Report the current state of mute for the selected channel

Return Values

The command will return the mute status (On=1, Off=0) in the same format as the command.

Appendices ~ Appendix F: Serial Commands

NLP

This command changes or reports back the state of the nonlinear processing for a microphone.

DEVICE] NLP <CH> <X>

Explanation

<CH>

CH= 1-8 Parameter to apply to the specified microphone channel

CH= * Parameter to apply command to all microphone channels

<X>

X=0 Parameter to set the state to OFF

X=1 Parameter to set the state to soft

X=2 Parameter to set the state to medium

X=3 Parameter to set the state to aggressive

X=Null Parameter to return the current state

Return Values

The command will return the updated condition (0=Off, 1=Soft, 2=Medium, 3=Aggressive) of the nonlinear processing in the same format as the command.

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Page 56
Image 56
ClearOne comm AP800 operation manual Mute, Explanation, Return Values, Appendices ~ Appendix F Serial Commands