ClearOne comm AP800 Serial Commands, 40Appendices ~ Appendix F Serial Commands, Error Codes

Models: AP800

1 68
Download 68 pages 59.79 Kb
Page 44
Image 44
40Appendices ~ Appendix F: Serial Commands

40Appendices ~ Appendix F: Serial Commands

Note: Using the all-mic toggle might not produce the desired result, depending on the state the mics are in. For example, if one mic is muted and all other mics are not, an all-mic toggle would mute all others, but unmute that particular mic.

Error Codes

Error 1

The address is not valid/out of range or an invalid character.

Error 2

Could not extract a command from the string received.

Error 3

Serial overrun.

Error 4

Reserved.

Error 5

Invalid parameter.

Error 6

Unrecognized command.

The command string will then be explained (where necessary), followed by the returned values and (where necessary) an example.

AP800 Serial Commands

Command

Function

Command

Function

AAMB

Enable/disable adaptive ambient*

NOM

Enable/disable NOM attenuation*

MDMODE

Enable/disable modem mode

FMP

Enable/disable first mic priority

AGC

Enable/disable AGC*

OFFA

Set/report off attenuation

MEQ

Set/report three-band equalization*

FPP

Set/report front-panel passcode

AMBLVL

Set/report ambient level

PAA

Enable/disable PA adaptive mode

MHP

Enable/disable high-pass filter*

GAIN

Set/report gain setting*

BAUD

Set/report RS-232 port baud rate

PCMD

Program/report GPIO control pin

MINIT

Set/report modem initialization string

GATE

Report mic gating status

CHAIRO

Enable/disable chairman override*

PEVNT

Program/report GPIO status pin

MLINE

Set/report mic/line level*

GMODE

Set/report gating mode*

DECAY

Set/report decay rate

PP

Enable/disable phantom power*

MMAX

Set/report max. number/mics

GRATIO

Set/report gate ratio

DFLTM

Set/report default meter

PRESET

Set/report active preset

MPASS

Program modem password string

HOLD

Set/report hold time

EC

Enable/disable echo canceller*

REFSEL

Set/report output for EC reference

MREF

Set/report echo canceller reference*

LFP

Enable/disable front-panel lock

ERL

Return ERL for a mic channel*

TOUT

Set/report inactivity timeout

MTRX

Program/report matrix configuration*

LMO

Set/report last-mic-on mode

ERLE

Return ERLE for a mic channel*

UID

Returns unit identification number

MUTE

Set/report mute status*

LVL

Report level*

EQ

Enable/disable equalization*

VER

Return current version of firmware

NLP

Set/report nonlinear processing*

MASTER

Set/report master/slave settings

FLOW

Enable/disable flow-control

* Applied to a specific channel

 

 

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760