FLOW

44

FLOW

This command selects or reports whether hardware flow control is enabled or disabled for the AP800. Hardware flow control is implemented using RTS and CTS.

[DEVICE] FLOW <X>

Explanation

<X>

X=0 Sets flow control to OFF

X=1 Sets flow control to ON

X=Null Parameter to return the current mode

Return Values

The command will return the updated condition (On=1, Off=0) of the AP800 in the same format as the command.

Appendices ~ Appendix F: Serial Commands

FMP

This command selects or returns the status of the first microphone priority mode for the AP800.

[DEVICE] FMP <X>

Explanation

<X>

X=0 Parameter to select first microphone priority mode to OFF

X=1 Parameter to select first microphone priority mode to ON

X=Null Parameter to return the current mode

Return Values

The command will return the updated condition (On=1, Off=0) of first mic priority mode in the same format as the command.

FMP

This command selects or returns the current status of the first microphone priority mode for the AP800.

[DEVICE] FMP <X>

Explanation

<X>

X=0 Parameter to select first microphone priority mode to OFF

X=1 Parameter to select first microphone priority mode to ON

X=Null Parameter to return the current mode

Return Values

The command will return the updated condition (On=1, Off=0) of first mic priority mode in the same format as the command.

FPP

This command sets and reports the current passcode setting for the AP800.

[DEVICE] FPP <XXXXX>

Explanation

<XXXXX>

X=1

▲ button

X=2

ENTER button

X=3

ESC button

X=4

▼ button

X=5

METER button

X=6

INPUT button

X=7

SYSTEM button

X=8

OUTPUT button

X=9

ROUTING button

X=Null

Parameter to return current passcode

Return Values

The command returns the current or updated condition of the front panel passcode.