PEVNT

Appendices ~ Appendix F: Serial Commands

PEVNT

This command programs or returns the program of the GPIO status pins from the serial port. The command line follows the same format as shown in the PCMD example above.

[DEVICE] PEVNT <LOCATION> <EVENT>

Explanation

<LOCATION>

LOCATION=1

Status A pin 2 active

LOCATION=2

Status A pin 2 inactive

LOCATION=3

Status A pin 4 active

LOCATION=4

Status A pin 4 inactive

LOCATION=5

Status A pin 6 active

LOCATION=6

Status A pin 6 inactive

LOCATION=7

Status A pin 8 active

LOCATION=8

Status A pin 8 inactive

LOCATION=9

Status A pin 10 active

LOCATION=10

Status A pin 10 inactive

LOCATION=11

Status A pin 12 active

LOCATION=12

Status A pin 12 inactive

LOCATION=13

Status A pin 14 active

LOCATION=14

Status A pin 14 inactive

LOCATION=15

Status A pin 16 active

LOCATION=16

Status A pin 16 inactive

LOCATION=17

Status B pin 2 active

LOCATION=18

Status B pin 2 inactive

LOCATION=19

Status B pin 4 active

LOCATION=20

Status B pin 4 inactive

LOCATION=21

Status B pin 6 active

LOCATION=22

Status B pin 6 inactive

LOCATION=23

Status B pin 8 active

LOCATION=24

Status B pin 8 inactive

LOCATION=25

Status B pin 10 active

LOCATION=26

Status B pin 10 inactive

LOCATION=27

Status B pin 12 active

LOCATION=28

Status B pin 12 inactive

LOCATION=29

Status B pin 14 active

LOCATION=30

Status B pin 14 inactive

LOCATION=31

Status B pin 16 active

LOCATION=32

Status B pin 16 inactive

55

<EVENT>

EVENT=String Pin will execute string when actuated EVENT=Null Parameter to return the current programming for the pin

EVENT=Clear Parameter to clear current programming (do nothing state)

EVENT LIST: LFP, PRESET, MUTE, GAIN, AGC, EQ, GMODE, CHAIRO

Return Values

The command returns the updated condition of the pin in the same format as the command. If the command did not alter the state, the command returns the event for which the pin is programmed.

Preset command note:

PRESET has two status parameters which can be set in a PEVNT command line: preset and NOT preset. To indicate NOT preset, add “!” to the end of the string. For example, this could be used to show when PRESET 1 occurs and then shut off if any other preset is selected. You would enter PRESET 1 in the active location and PRESET 1! in the inactive location for the desired pin.