ClearOne comm AP800 Baud, Decay, Chairo, Dfltm, Appendices ~ Appendix F Serial Commands

Models: AP800

1 68
Download 68 pages 59.79 Kb
Page 46
Image 46
Appendices ~ Appendix F: Serial Commands

42

Appendices ~ Appendix F: Serial Commands

BAUD

This command selects or returns the baud rate for the RS-232 port on the AP800.

[DEVICE] BAUD <X>

Explanation

<X>

X=1 Selects 9,600 baud (bps) rate

X=2 Selects 19,200 baud (bps) rate

X=3 Selects 38,400 baud (bps) rate

X=Null Parameter to return the baud (bps) rate

DECAY

This command changes or reports back the setting of the decay rate for a given AP800.

[DEVICE] DECAY <X>

Explanation

<X>

X=1 Parameter to set the decay rate to slow X=2 Parameter to set the decay rate to medium X=3 Parameter to set the decay rate to fast X=Null Parameter to return the current decay rate

Return Values

The command will return the updated condition (1=9,600 baud, 2=19,200 baud, 3=38,400 baud) of the baud rate in the same format as the command.

CHAIRO

This command changes or reports back the state of the chairman override for a microphone channel.

[DEVICE] CHAIRO <CH> <X>

Explanation

<CH>

CH= 1-8 Parameter to apply to the specified microphone channel

CH= * Parameter to apply command to all microphone channels

<X>

X=0 Parameter to set the state to OFF

X=1 Parameter to set the state to ON

X=2 Parameter to toggle the state from one

state to the other (regardless of current state) X=Null Parameter to return the current state

Return Values

The command will return the updated condition (On=1, Off=0) of the chairman override in the same format as the command.

Return Values

The command will return the updated decay rate for the selected AP800 in the same format as the command.

DFLTM

This command changes and reports back the status of the default meter.

[DEVICE] DFLTM <CH> <W>

Explanation

<CH>

CH= 1-8 Parameter to apply to the specified channel CH= A-D Parameter to apply to the specified channel CH= Null Parameter to return the current state of the

defaultmeter <W>

W= I Parameter to specify an input channel W= O Parameter to specify an output channel

Return Values

The command will return the current default meter in the same format as the command.

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Page 46
Image 46
ClearOne comm AP800 Baud, Decay, Chairo, Dfltm, Appendices ~ Appendix F Serial Commands, Explanation, Return Values