REFSEL

56

PP

This command changes or reports back the state of the phantom power for a microphone.

[DEVICE] PP <CH> <X>

Explanation

<CH>

CH= 1-8 Parameter to apply to the specified microphone channel

CH= * Parameter to apply command to all microphone channels

<X>

X=0 Parameter to set the state to OFF X=1 Parameter to set the state to ON X=Null Parameter to return the current state

Return Values

The command will return the updated condition (On=1, Off=0) of the phantom power in the same format as the command.

Appendices ~ Appendix F: Serial Commands

REFSEL

This command selects or returns the output to be used as the EC Reference 1 and EC Reference 2.

[DEVICE] REFSEL <X> <OUTPUT>

Explanation

<X>

X=1 Parameter to select the EC Reference 1

X=2 Parameter to select the EC Reference 2

X=3 Parameter to select the G-Link EC Ref bus

<OUTPUT>

OUTPUT=1-8 Parameter to select 1-8 as the EC reference OUTPUT=A-D Parameter to select A-D as the EC reference OUTPUT=E Parameter to select G-Link EC Ref bus as the EC Reference

OUTPUT=F Parameter to select none

OUTPUT=Null Parameter to return the EC reference value

Return Values

Command returns the updated condition of the reference select in the same format as the command.

PRESET

This command selects or reports the current preset

TOUT

 

configuration used by the AP800.

This command sets or reports the current inactivity timeout before

[DEVICE] PRESET <X>

returning to the title screen used by the unit.

 

Explanation

[DEVICE] TOUT <X>

Explanation

<X>

X=1-6 Sets the preset to the number specified

<X>

X=Null Parameter to return the current preset

X=0 Disables inactivity timeout

 

X=1-15 Sets the number of minutes specified

Return Values

X=Null Parameter to return the current number of minutes

The command will return the current preset (updated, if the

 

command changed the preset).

Return Values

 

The command will return the current timeout value (updated, if

 

the command changed the timeout).