MTEK6000 SERIES USER'S MANUAL
Open Door Alarm (optional)
The Open Door (tamper) alarm is initiated when the door of the MTEK6000 opens. When this occurs, a full
Software Error Alarm
If there is a fault in the software, the Software Error alarm will initiate.
MEMORY (HISTORY LOGGING)
The MTEK6000 has a total of 96K (Main 64K bank and Auxiliary 32K bank) of RAM for database, audit trail, and history logging. With the large memory capacity, over 81,000 bytes of
NOTE
The size of the block CANNOT be changed once the history process has been created in the unit. A complete download would be required to reset the database and change the device's memory assignment.
The total number of records (entries) the device can log depends on the number of items you wish to log:
January 2002
# of Record = | 81,000 | . |
| 4 x (# of items to log +1) |
NOTE
Since there are two individual data banks, you may not be able to access all of the memory. The configuration must be optimized to utilize most or all of the memory.
Data may be collected over the telephone lines via the modem,
1.Billing information
2.Measurement reports for utility and customer management.
3.System analysis using flow rate and pressure.
4.Support for estimating gas volume consumption in cases of meter or instrument malfunction.
3