MTEK6000 SERIES USER'S MANUAL

APPENDIX A: PROCESS CONFIGURATION STANDARD

The MTEK6000 uses Process configuration for database organization and management.

Table A-1: Standard display mode and function keys for MTEK6000 EFC

Label I.D.

Description

Address

F1

1

CV

Corr Volume MCF

051102

F2

2

UV

Uncor Volume MCF 051108

F3

3

PR

PRessure PSG

030302

F4

4

FT

Flow Temp F

020304

 

5

FR

Flow Rate MCH

050302

F5

6

SV

Supply Volts VDC

020309

 

7

CT

Case Temp F

020302

 

8

FL

Flow Constant

050601

 

9

PD

Prev Day vol MCF

050903

 

10

CD

Curr Day vol MCF

050905

 

11

CU

Cubic Unit/p CFP

050802

 

12

PS

Press Scale PSG

020402

Table A-2: Standard

alarms for

MTEK6000 EFC

 

Alarms

Alarm Code

First Time Power

130401

Low Supply Volts

130501

High Flow Rate

130601

Low Flow Rate

130701

High Pressure

140401

Low Pressure

140501

Current Day Flow

140601

Faulty Counter

140701

*High Temperature

150401

*Low Temperature

150501

Lost Pressure

150601

*Lost Temperature

150701

LowVolt Shutdown

160401

Open Door

160501

Software Error

160601

Switch #1 Alarm

160701

Switch #2 Alarm

170401

*MTEK6000 EFCV only

Table A-3: Standard history data stored in the MTEK6000 EFC and EFCP

40 days of daily corrected volume

40 days of daily uncorrected volume

40 days of daily maximum flow rate

40 days of daily minimum flow rate

40 days of daily average pressure

40 days of daily average temperature

40 days of hourly corrected volume

40 days of hourly uncorrected volume

40 days of hourly average pressure

40 days of hourly average temperature

40 days of hourly instantaneous supply voltage (snapshots).

40 days of hourly case temperature (snapshots)

January 2002

A-1