Compaq MTEK6000 Units of Measure, Flow & Volume, Accumulations, Static Pressure, Pipe & Orifice

Models: MTEK6000

1 81
Download 81 pages 16.91 Kb
Page 65
Image 65

MTEK6000 SERIES USER'S MANUAL

It is disabled if set to 0. In this mode, the EFC should be configured to wake up on the number of pulses entered along with an hourly scheduled wake-up to record history

Units of Measure

data. Therefore, the wake up interval (seconds) parameter should be set to 3600. The Default value is 0.

The MTEK6000 can be configured to calculate volume and flow with English or Metric units. The database ca be setup for the following units of measure:

Flow & Volume

ft3 (cubic feet)

Accumulations

M3 (cubic meters)

Static Pressure

PSI (pounds per square inch)

 

Kpa (Kilopascals)

 

Kg / cm2 (kilograms per square centimeter)

 

Bars

 

MBars (millibars)

 

Atmospheres

 

mmHg (millimeters of mercury)

 

mmH2O (millimeters of water)

 

MH2O (meters of water)

 

inH2O (inches of water)

Temperature*

°F

 

°C

Differential

inH2O (inches of water)

Pressure

mmH2O (mm of water)

Pipe & Orifice

inches

Diameter

centimeters

*The units for temperature are automatically set for °F or °C when the units for volume and flow are chosen. Choosing English units (cubic feet) will set the temperature to F, etc.

January 2002

C - 7

Page 65
Image 65
Compaq MTEK6000 Units of Measure, Flow & Volume, Accumulations, Static Pressure, Temperature Differential, Pipe & Orifice