Table A-9: Standard history data stored in the MTEK6000 EFC w/ 2 Aux Pressure

40 days of daily corrected volume

40 days of daily uncorrected volume

40 days of daily maximum flow rate

40 days of daily minimum flow rate

40 days of daily average pressure

40 days of daily maximum pressure

40 days of daily minimum pressure

40 days of daily average aux. pressure 1

40 days of daily average aux. pressure 2

40 days of daily maximum aux. pressure 1

40 days of daily maximum aux. pressure 2

40 days of daily minimum aux. pressure 1

40 days of daily minimum aux. pressure 2

40 days of hourly average aux. pressure 1

40 days of hourly average aux. pressure 2

40 days of hourly uncorrected volume

40 days of hourly average pressure

Table A-10: Standard display mode and function keys for MTEK6000 EFC2 w/2

Aux Pressure

Label

I.D.

Description

Address

F1

1

CV

Corr Volume MCF

051102

F2

2

UV

Uncor Volume MCF 051108

F3

3

PR

PRessure PSG

030302

F4

4

FT

Flow Temp deg F

020304

 

5

F1

Flow rate 1 MCH

050302

 

6

UF

Uncorr Flow R1

050306

 

7

FC

Flow Constant 1

050601

 

8

PD

Prev Day Vol 1

050903

 

9

CD

Curr Day Vol 1

050905

 

10

CU

Cubic Unit/p 1

050802

 

11

C2

Corr vol 2 MCF

061102

 

12

U2

Uncorr vol 2 MCF

061108

 

13

F2

Flow rate 2 MCH

060302

 

14

UF

Uncorr Flow R2

060306

 

15

FC

Flow Constant 2

060601

 

16

PD

Prev Day Vol 2

060903

 

17

CD

Curr Day Vol 2

060905

 

18

CU

Cubic Unit/p 2

060802

 

19

A1

Aux 1 press PSG

020305

 

20

A2

Aux 2 press PSG

020306

 

21

SV

Supply Volts VDC

020309

 

22

CT

Case Temp F

020302

 

23

PR

PRessure SCL

020402

 

24

A1

Aux press 1 SCL

020404

 

25

A2

Aux press 2 SCL

020405

 

37

TF

Total Flow Rate

370201

A-4

January 2002

Page 50