Chapter 8 - LED Patterns and Test Switch Settings

31

IntraPort Enterprise-8 Switch Settings

The switch for Ethernet 0:0 controls the entire device. For example, if you set the switch for Ethernet 0:0 to “3” and download new software to the device, the other interfaces will auto- matically receive the software update from Ethernet 0:0 via the backplane. In general, the only time you should use an individual RIOP card’s switch is when the card is unable to communi- cate with the backplane for some reason.

0Normal Operation

1Unused*

2Unused*

3Run Boot ROM Downloader

4Unused*

5Erase Flash ROM (OS and Configuration)

6Erase Flash ROM (Configuration Only)

7Unused*

8Unused*

9Allow letmein password for 5 minutes after powerup

ΜCaution: Settings marked with an asterisk may erase your Flash ROM. Please do not use these settings without first contacting Compatible Systems’ Technical Support.