CANpro/104 User Manual

Example #2: Memory Address 0x0C8000 (this address is below the 1-Meg boundary) 0x0C8000 = 0000.1100.100X.XXXX.CJJJ.JJJJ (binary)

 

Address

Bit

J3A or J3B

Installed

 

Bit

Value

Position

or Removed

 

23

0

J3A-2

Removed

 

22

0

J3A-3

Removed

 

21

0

Address Bit always decoded as “0”

 

20

0

Address Bit always decoded as “0”

 

19

1

J3A-4

Installed

 

18

1

J3A-5

Installed

 

17

0

J3A-6

Removed

 

16

0

J3B-1

Removed

 

15

1

J3B-2

Installed

 

14

0

J3B-3

Removed

 

13

0

J3B-4

Removed

 

Table 9

 

 

 

Example #3:

I/O Address 0x340 (BasicCAN mode)

 

 

0x340 = XXXX.XXXX.XXXX.X011.01CJ.JJJJ (binary)

 

 

 

 

 

 

Address

Bit

J3A or J3B

Installed

 

Bit

Value

Position

or Removed

 

23 -> 11

X

---

---

 

10

0

J3A-6

Removed

 

9

1

J3B-1

Installed

 

8

1

J3B-2

Installed

 

7

0

J3B-3

Removed

 

6

1

J3B-4

Installed

 

Table 10

 

 

 

Example #4:

I/O Address 0x600 (PeliCAN mode)

 

 

0x600 = XXXX.XXXX.XXXX.X110.CJJJ.JJJJ (binary)

 

 

 

 

 

 

Address

Bit

J3A or J3B

Installed

 

Bit

Value

Position

or Removed

 

23 -> 11

X

---

---

 

10

1

J3A-6

Installed

 

9

1

J3B-1

Installed

 

8

0

J3B-2

Removed

Table 11

11

www.connecttech.com

CTIM-00043 (0.01) 1/15/2010

 

800-426-8979 519-836-1291

 

Page 11