Cornelius 1550 Unit Maintenance Cleaning Condenser Coil, Beer Flow Rateadjustment Adjustment

Models: 1550

1 36
Download 36 pages 26.56 Kb
Page 24
Image 24
CORNELIUS BEER FAUCET

Adjusting Beer Kegs Secondary CO2 Regulators.

Beer kegs secondary CO2 regulators pressures adjustments require calculations of each beer system total beer system pressure. Total beer system pressure, required to push beer from keg to faucet, is the result of comput- ing length of beer line of a certain size, vertical line lift, and internal keg pressure. Internal keg pressure differs from one beer brand to another

Contact your local Beer Distributor for proper secondary CO2 regulators pressure settings. Adjust secondary CO2 regulators by loosening adjusting screws lock nuts, then turn adjusting screws to the right (clockwise) until regulator gages register recommended pressures. Tighten adjustments screws lock nuts after adjustments have been completed.

Adjusting Dispensed Beer Flow Rate.

(see Figure 6)

Adjust the beer flow rate at approximately 2-ounces per second by rotating the beer faucet compensator adjust- ing screw to the left (counterclockwise) for a higher beer flow rate or to the right (clockwise) for a lower beer flow rate.

CORNELIUS BEER FAUCET

PERLICK BEER FAUCET

BEER FLOW RATE

BEER FLOW RATEADJUSTMENT

ADJUSTMENT

FIGURE 6. BEER FAUCET ADJUSTMENT

UNIT MAINTENANCE

CLEANING CONDENSER COIL

(see Figure 5)

NOTE: Air circulation through the condenser coil, required to cool the coil, is drawn in through grille on Unit front panel and is exhausted out through grilles on sides and back of the Unit. Restricting air flow through the condenser coil will decrease cooling efficiency of the Unit.

Area in front, sides, and back of the Unit must be kept free of obstructions at all times which would prevent air flow in and out of the Unit.

An excessive accumulation of dust, lint, and grease on the condenser coil will restrict air flow through the coil which will decrease cooling efficiency of the Unit. The Unit condenser coil should be periodically cleaned by per- forming the following:

1. Unplug Unit power cord from electrical outlet.