TROUBLESHOOTING

TROUBLESHOOTING

IMPORTANT: Only qualified Personnel should service internal components or electrical wiring.

WARNING: If repairs are to be made to the beer system, close shutoff valve in applicable beer inlet line, then relieve system pressure before proceeding. If repairs are to be made to the CO2 system, shut off CO2 supply, shut off beer keg tappers CO2 lines shutoff valves,

then relieve system pressure before proceeding. If repairs are to be made to the refrigeration system, make sure electrical power is disconnected from the Unit.

Trouble

Probable Cause

Remedy

TROUBLESHOOTING CO2 SYSTEM

NO CO2 GAS PRESSURE ON BEER SYSTEMS.

A.Empty CO2 cylinder.

B.CO2 shutoff valve closed at CO2 cylinder.

C.CO2 shutoff valves in lines leading to beer kegs tappers closed.

A.Replenish CO2 supply as instructed.

B.Open CO2 shutoff valve at CO2 cylinder.

C.Open CO2 shutoff valves in lines leading to beer kegs tappers.

 

D.

CO2 regulators improperly

D.

Adjust CO2 regulators as

 

 

adjusted.

 

instructed.

 

E.

Leak in CO2 system.

E. Repair leaks in CO2 system.

INSUFFICIENT CO2 GAS

A.

Empty CO2 cylinder.

A. Replenish CO2 supply as

PRESSURE ON BEER

 

 

 

instructed.

SYSTEMS.

 

 

 

 

 

B. CO2 shutoff valve in CO2

B. Open CO2 shutoff valve all the

 

 

system partially closed.

 

way.

 

C.

CO2 regulator improperly

C.

Adjust CO2 regulator as

 

 

adjusted.

 

instructed.

 

D.

Leak in CO2 system.

D. Repair leak in CO2 system.

Trouble

 

Probable Cause

 

Remedy

 

 

 

TROUBLESHOOTING BEER SYSTEM

 

 

 

 

 

 

DISPENSED BEER FLOW

A.

Beer faucet not properly

A. Adjust dispensed beer flow rate

RATE TOO LOW.

 

adjusted for beer flow rate.

 

as instructed.

 

B.

Insufficient CO2/gas pressure

B.

Refer to ‘‘INSUFFICIENT CO2

 

 

on beer system.

 

GAS PRESSURE ON BEER

SYSTEM’’ in this section.