3.Web Control

3.1Projector Web Control - Alert Settings (continued) The Alert Items are shown below.

Item

Description

 

 

Alarm Time

Configures the time to alert.

(Only Lamp Time Alarm and Filter Time Alarm.)

 

SNMP Trap

Click the [Enable] check box to enable SNMP Trap alerts.

Send Mail

Click the [Enable] check box to enable e-mail alerts.

(Except Cold Start and Authentication Failure.)

 

 

Configures the subject line of the e-mail to be sent.

Mail Subject

The length of the subject line can be up to 100 alphanumeric

characters.

 

 

(Except Cold Start and Authentication Failure.)

 

Configures the text of the e-mail to be sent.

 

The length of the text can be up to 1024 alphanumeric

Mail Text

characters, but if you are using some of special characters

below the length may be shorter.

 

 

Special characters " ' : & , % \ and space

 

(Except Cold Start and Authentication Failure.)

Click the [Apply] button to save the settings.

NOTE • The trigger of Filter Error e-mail is depending on the FILTER MESSAGE setting in the SERVICE item of the OPTION menu which defines the period until the filter message is displayed on the projector screen. An e-mail will be sent when the usage time of the filter exceeds the time limit that is set. No notification e-mail will be sent if the FILTER MESSAGE is set to TURN OFF. (OPTION menu in the Operating Guide)

Lamp Time Alarm is defined as a threshold for e-mail notification (reminder) of the lamp time. When the lamp hour exceeds the limit that is configured in the Projector Web Control, an e-mail will be sent.

Filter Time Alarm is defined as a threshold for e-mail notification (reminder) of the filter time. When the filter hour exceeds the limit that is configured in the Projector Web Control, an e-mail will be sent.

Filter Status Notification can be enabled for both or either one of Status

1 and 2. These notifications are equivalent to the changing of the FILTER indicator on the projector. (Status 1: off to orange, Status 2: orange to red) Refer to the Operating Guide for details of the FILTER indicator.

26

Page 26
Image 26
Crestron electronic CP-X8150 Alarm Time, Only Lamp Time Alarm and Filter Time Alarm, Snmp Trap, Mail Subject, Mail Text