Crestron MPS-250 Multimedia Presentation System 250
Turn On the System To turn on the system, press any of the source buttons on the control center. The
selected source will be routed to all of the outputs.
NOTE: Typically, signal routing information is not displayed on the front panel of
the MPS-250. However, if an output button on the MPS-250 was pressed at any
point during operation, routing information will be displayed and updated should any
changes to routing be made.
Turn Off the MPS-250 To turn off the system, press the POWER button.
Raise or Lower the Projection
Screen To raise or lower the projection screen, press the SCREEN button. The front panel
of the MPS-250 will also indicate the screen’s status.
NOTE: This function will only work if a projection screen’s control lines have been
connected to RELAY 1 (up control) and RELAY 2 (down control).
Adjust the Volume Level To raise the volume level, press the VOL UP button. To lower the volume, press the
VOL DOWN button. The volume control buttons will only control the volume
parameter that was selected when the Volume Control Mode was specified as
described on page 46.
Mute Audio To mute the audio output, press the MUTE button. To unmute, press the MUTE
button again. The front panel of the MPS-250 will indicate the status of the mute
function.
Adjust Lighting To toggle between preset light settings, press either of the LIGHTS buttons. The
front panel of the MPS-250 will indicate the selected preset light setting.
NOTE: This function will only work if a CLS-C6, infiNET switch, or infiNET
dimmer was previously identified and connected to the MPS-250. The CLS-C6 can
be identified as a Cresnet device in the MPS-250 setup screens as described on page
66. Crestron’s infiNET switches and dimmers require a C2N-MNETGW to be
identified as described on page 66 in addition to identifying the individual switch
and/or dimmer with a unique identity code (MNET ID) using Crestron Toolbox.
CLW-DIM1RF and CLW-DIMS1RF dimmers use MNET IDs 03 and 04 while
CLW-SW1RF and CLW-SWS1RF switches use MNET IDs 05 and 06. For
information on identifying infiNET switches and dimmers, refer to the Crestron
Toolbox help file.
Operations Guide – DOC. 6647A Multimedia Presentation System 250: MPS-250 • 81