Crown Audio IQ P.I.P.-DSP Quick Install Procedure, Prepare the IQ-P.I.P.-DSP, Install the wiring

Models: IQ P.I.P.-DSP

1 27
Download 27 pages 37.81 Kb
Page 5
Image 5
Quick Install Procedure

IQ–P.I.P.–DSPProgrammable Input Processor with DSP for IQ Systems

Quick Install Procedure

This procedure is provided for those who are already familiar with Crown’s IQ System and who would like to install the IQ–P.I.P.–DSPin the shortest time possible. Less experienced installers or those wishing a full explanation of the installation procedure are encouraged to go to Section 4 where the full installation procedure is described.

Prepare the IQ–P.I.P.–DSP:

1.Set the IQ address switch SW1 (Figures 4.1 and 4.2) on the IQ–P.I.P.–DSPto an unused IQ address. (Tip: Record the IQ address on the small blank label that is provided on lower right corner of the P.I.P. panel.)

2.Set jumpers JP4 and JP5. Set both jumper JP4 and JP5 to the “OUT” position if either a PIP2-compatible or Macro-Tech 5000VZ amplifier will be used (Figures 2.1 and 4.7). Both JP4 and JP5 should be set to the “IN” position for all other amplifiers.

Prepare the amplifier:

3.Turn down the level controls of the amplifier and turn off the amplifier.

4.Unplug the power cord of the amplifier from the AC mains.

5.Remove the existing P.I.P. or cover panel from the amplifier back panel (two screws).

6.Set the amplifier input sensitivity switch to 0.775 V. (See the Reference or Owner’s Manual of the amplifier.)

Install the IQ–P.I.P.–DSP into the amplifier:

7.Carefully ground yourself to the chassis of the amplifier before installing the IQ–P.I.P.– DSP. It is a good idea to maintain ground contact between yourself and the amplifier while inserting the module into the P.I.P. card rails in the next step.

8.Install the IQ–P.I.P.–DSPinto the amplifier:

Standard P.I.P. Amplifiers: Align the edges of the IQ–P.I.P.–DSPin the P.I.P. card rails and firmly push the unit in until it is seated against the mounting bracket (Figure 4.4).

PIP2 Compatible Amplifiers: Connect the PIP2 input adapter to the amplifier input cables. Plug the IQ–P.I.P.–DSPinto the PIP2 input adapter and insert the assembly into the P.I.P. opening in the back of the amplifier (Figures 4.5 and 4.6).

9.Tighten the two P.I.P. mounting screws until it is secured to the amplifier back panel.

Install the wiring:

10.Connect the IQ–P.I.P.–DSPto the IQ System via the Crown Bus (see Section 4.6 if more information is needed).

11.Connect the audio signal wiring to the IQ–P.I.P.–DSP. This includes the XLR input wiring and the phone jack daisy chain wiring—if desired (see Section 4.7 if more information is needed). Note: FCC and EC EMI regulations require that the EMI suppression core provided with this P.I.P. be installed on the daisy chain cables, if used.

12.Connect the amplifier back to the AC receptacle. Note: The IQ–P.I.P.–DSP may require an external power supply in some amplifiers. See Section 4.8 for more information.

Adjust the levels and scale factors:

13.Turn the level controls of the amplifier to their full setting. Use the software-controlled input attenuators on the IQ–P.I.P.–DSPto adjust the input levels down.

14.Standard P.I.P. Amplifiers: Manually configure the scaling factors of the IQ–P.I.P.–DSPwith appropriate IQ System software.

PIP2 Compatible Amplifiers: The scaling factors will be automatically set.

Reference Manual

Page 5

Page 5
Image 5
Crown Audio IQ P.I.P.-DSP Quick Install Procedure, Prepare the IQ-P.I.P.-DSP, Prepare the amplifier, Install the wiring