CY7C1354C
CY7C1356C
PRELOAD allows an initial data pattern to be placed at the latched parallel outputs of the boundary scan register cells prior to the selection of another boundary scan test operation.
The shifting of data for the SAMPLE and PRELOAD phases can occur concurrently when
BYPASS
When the BYPASS instruction is loaded in the instruction register and the TAP is placed in a
register is placed between the TDI and TDO balls. The advantage of the BYPASS instruction is that it shortens the boundary scan path when multiple devices are connected together on a board.
Reserved
These instructions are not implemented but are reserved for future use. Do not use these instructions.
TAP Timing
12
Test Clock
(TCK)tTH
tTMSS tTMSH
Test Mode Select (TMS)
tTDIS tTDIH
Test
3 | 4 | 5 | 6 |
tTL tCYC
tTDOV
tTDOX
| Test |
|
|
|
| (TDO) |
|
|
|
| DON’T CARE | UNDEFINED |
|
|
TAP AC Switching Characteristics Over the Operating Range[10, 11] |
|
| ||
Parameter | Description | Min. | Max. | Unit |
Clock |
|
|
|
|
tTCYC | TCK Clock Cycle Time | 50 |
| ns |
tTF | TCK Clock Frequency |
| 20 | MHz |
tTH | TCK Clock HIGH time | 20 |
| ns |
tTL | TCK Clock LOW time | 20 |
| ns |
Output Times |
|
|
| |
tTDOV | TCK Clock LOW to TDO Valid |
| 10 | ns |
tTDOX | TCK Clock LOW to TDO Invalid | 0 |
| ns |
|
|
|
| |
tTMSS | TMS | 5 |
| ns |
tTDIS | TDI | 5 |
| ns |
tCS | Capture | 5 |
| ns |
Hold Times |
|
|
|
|
tTMSH | TMS Hold after TCK Clock Rise | 5 |
| ns |
tTDIH | TDI Hold after Clock Rise | 5 |
| ns |
tCH | Capture Hold after Clock Rise | 5 |
| ns |
Notes:
10.tCS and tCH refer to the
11.Test conditions are specified using the load in TAP AC test Conditions. tR/tF = 1 ns.