Installation Instructions

5.Slide the end of the appliance cord into the strain relief from the bottom of the box.

6.Connect the white (neutral) wire to the neutral terminal in the box.

7.Connect the L1 wire to the L1 power supply terminal in the box.

8.Connect the L2 wire to the L2 power supply terminal in the box.

9.If using a 4-wire connection, connect the ground wire to the grounding screw inside the box using a loop or spade terminal.

10.Tighten the strain relief so that the appliance cord is held snuggly in place.

11.Replace the range electrical access cover.

L1 terminal

Neutral terminal

L2 terminal

Neutral to ground jumper link removed

Grounding screw

L2 wire

Green wire

White wire

Strain relief

L1 wire

4-wire ApplianceCord Connection(preferred)

L2

Neutral

Ground

L1

14-50P Plug

Bare wire connections

Loop and spade terminal connections

L1 terminal

Neutral terminal

L2 terminal

Neutral to ground jumper link

L1 wire

White wire

L2 wire

Strain relief

3-wire Appliance CordConnection -Where Local Code Permits

L1

Neutral

L2

10-50P Plug

15