Installation Instructions
5.Slide the end of the appliance cord into the strain relief from the bottom of the box.
6.Connect the white (neutral) wire to the neutral terminal in the box.
7.Connect the L1 wire to the L1 power supply terminal in the box.
8.Connect the L2 wire to the L2 power supply terminal in the box.
9.If using a
10.Tighten the strain relief so that the appliance cord is held snuggly in place.
11.Replace the range electrical access cover.
L1 terminal
Neutral terminal
L2 terminal
Neutral to ground jumper link removed
Grounding screw
L2 wire
Green wire
White wire
Strain relief | L1 wire |
L2
Neutral
Ground
L1
Bare wire connections
Loop and spade terminal connections
L1 terminal
Neutral terminal
L2 terminal
Neutral to ground jumper link
L1 wire
White wire
L2 wire
Strain relief
L1
Neutral
L2
15