Installation Instructions
Electrical Connection (cont.)
Connecting Conduit to the Range
warning
Do not connect the green appliance wire to the neutral (white) supply wire unless local building codes permit.
1.Remove the range electrical access cover from the back of the range.
2.IMPORTANT: If using a
Terminal block
Remove link on
3.Remove the nut from the conduit strain relief (not included).
4.Slide the wires and the end of the strain relief into the hole on the bottom of the range electrical box.
5.Before connecting the wires, slide the strain relief nut over the wires and thread it onto the conduit strain relief inside the box. Tighten into place.
6.Connect the white wire to the neutral terminal in the box.
7.Connect the black wire to the L1 power supply terminal.
8.Connect the red wire to the L2 power supply terminal.
9.If using a
Bare wire connections
Loop and spade terminal connections
L1 terminal
Neutral terminal
L2 terminal
Neutral to ground jumper link removed
Grounding screw Red wire
Green wire White wire
Black wire
Conduit strain relief nut
4-Wire Conduit
Connection
(preferred)
L1 terminal
Neutral terminal
Neutral to ground jumper link
L2 terminal
Black wire
White wire
Red wire
10. Replace the range electrical access cover. | Conduit strain |
| |
| relief nut |
3-Wire Conduit Connection -
Where Local Code Permits
16