Installation Instructions

Connecting the Conduit to the House Electrical Junction Box

warning

Do not ground the appliance to a gas supply pipe or hot water pipe.

Do not turn on power to the appliance without it being permanently grounded.

A grounded cold water pipe must have metal continuity to electrical ground and must not be interrupted by insulating materials. Any insulating materials must be jumpered with a length of No. 4 copper wire securely clamped to bare metal at both ends.

No. 4

copper wire

Meter or other

insulating device

Metal

water pipe

Clamps

Bare metal

Insulated Pipe Jumper

NOTE: The power supply must be properly polarized. Reverse polarity will result in continuous sparking of the electrodes, even after flame ignition. If there is any doubt as to whether the power supply is properly polarized or grounded, have it checked by a licensed electrician.

1.With the range positioned directly in front of the cabinet cutout, feed the appliance wires into the junction box. Depending upon local codes, utilize one of the three (3) methods shown to connect the appliance to the junction box.

2.Connect the white wire from the appliance to the neutral (white) supply wire in the junction box.

3.Connect the black wire from the appliance to the black (L1) power supply wire in the junction box.

4.Connect the red wire from the appliance to the red (L2) power supply wire in the junction box.

5.If using a 4-wire connection, connect the green wire to a grounded supply wire in the junction box or to a grounded cold water pipe. If connecting to a grounded cold water pipe:

Use a separate copper grounding wire (No. 10 minimum) to connect to the cold water pipe by means of a clamp and an external grounding connector screw.

If there are any materials that isolate the cold water pipe from ground, jumper it with a No. 4 copper wire, clamped on both ends.

6.Replace the junction box cover.

Connection to power supply

Junction box

RED WHITE

RED WHITE

GREEN BLACK

GREEN BLACK

4-Wire Conduit-Junction

Connection to

appliance

Box Connection

 

 

 

Separate No. 10 (minimum)

 

copper grounding wire

 

Connection to

 

 

power supply

 

 

Junction box

 

Fasten clamp

 

tightly on pipe

RED

WHITE

Wire nut

4 places

RED

WHITE

 

 

GREEN

BLACK

 

GREEN

 

BLACK

 

 

 

Connection to

appliance

3-Wire Conduit-Junction Box

Connection with External Ground

Connection to power supply

Junction box

Wire nut 3 places

3-WireConduit-Junction Connection to appliance

Box Connection

17