Installation Instructions

Rotating the Blower for Models:

EH3012, MH3012, EH3612, MH3612 and EH4212 (Models that are 12 inches high equipped with a single blower)

1.Place the hood assembly on a large flat surface.

2.Remove and save the four (4) screws and the duct col- lar from the top of the unit. See below.

3.Remove and save the four (4) screws and the cover plate that covers the hole on the back of the hood.

Duct Collar

Cover Plate

 

8.Disconnect the wiring harness connector from the blower motor.

9.While supporting the blower from below, remove the four (4) nuts that hold the blower and mounting plate in place. Remove the blower from the hood.

4.

Tip the hood back, so that it lays on its back with the

 

front pointing up.

5.

Remove the filters from the under side of the hood.

10.Remove and discard the mounting plate attached to the blower motor.

11.Remove the four (4) nuts that hold the rear mounting plate in place and remove it. See below.

Remove

and discard

6.

Locate the wiring harness. Cut the cable tie that takes

 

up the slack in the cable. It is located behind the panel

 

on the right side inside the hood. Also cut the two (2)

 

cable ties that hold the wiring harness to the brace

 

inside the hood, on the right side. See below.

7.

Remove and save the nut that holds the wiring harness

 

cable clamp in place. Remove and save the clamp.

Remove

cable clamp

Wiring

Harness

Remove cable ties

12.Attach the mounting plate removed in step 11 (rear mounting plate) to the blower motor.

Rear Mounting

Plate

10