Installation Instructions

12” high models with rear exhaust:

Center the transition over the duct collars while resting the unmodified edge on the top of the hood. Fasten in place using sheet metal screws (not included). Seal the base of of the transition with duct tape.

3.Find the temporary mounting bracket in the shipping box. Put the bracket against the wall and line up the center hole with the intersection of the bracket center lines on the wall. Make sure the anchors and/or screws used are strong enough to support the hood. Make sure drywall installations are properly reinforced.

Mounting Bracket Installation

1.Draw the horizontal center line for the temporary mounting brackets on the wall. The center line for the brackets is 2 1/8” (54 cm) below where the top of the hood will be located. The horizontal line marks the cen- ter line of the mounting screws that hold the temporary mounting brackets in place. IMPORTANT: Installing the brackets lower or higher than the center line shown will cause alignment problems during final installation.

2.Draw the two (2) vertical center lines for the brackets on the wall. They are located on both sides of the hood center line drawn on the wall before making the duct cut-out. The distance from the center line depends on the model. See the chart below.

TEMPORARY BRACKET CENTER LINE DISTANCE

ModelsF

EH3012, EH3018, MH3012, MH3018 12 3/8” (31.4 cm)

EH3612, EH3618, MH3612, MH3618 15 3/8” (39.1 cm)

EH4212, EH421818 3/8” (46.7 cm)

EH4812, EH4818, MH4812, MH4818 21 3/8” (54.3 cm)

 

EH5418

 

 

 

 

24 3/8” (61.9 cm)

 

 

2 1/8”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bracket

 

 

F

 

 

 

F

 

 

Bracket

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

location

 

 

 

Hood

location

 

 

 

 

 

 

 

 

 

 

 

 

 

location

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reinforced

Drywall

4.Mark the two mounting hole positions through the holes in the bracket. Drill the pilot holes for the screws or anchors and attach the brackets securely to the wall.

17