Installation Instructions

Verifying Proper Operation

Feature Keys Main Power

Switch

Filters

1.Make sure the main power switch is off.

2.Turn on power at the circuit

breaker panel or fuse box.

 

 

 

ON

 

 

 

3. Turn on the main power

 

 

 

OFF

 

 

 

switch.

 

 

 

 

 

 

 

 

 

 

4.Install the filter(s).

5.Touch the LIGHTS feature key. Verify that all the lights come on.

6.Touch the LIGHTS key again to turn the lights to the low setting.

7.Touch the LIGHTS key again to turn the lights off.

8.Touch the FAN feature key once and release. Verify that one light is showing on the fan speed indicator and that the fan is on at low speed. Touch and release the FAN key repeatedly, three times. Verify that with each touch of the key, the number of lights on the fan speed indicator increases and that the fan speed increases.

9.Touch the FAN key again to turn the fan off.

If the hood fails to operate properly:

Verify that power is supplied to the hood.

Check the electrical connections to ensure that the installation has been completed correctly.

Repeat the above test.

If the hood still does not work, contact an authorized Dacor service company at (800) 793-0093.

Do not attempt to repair the appliance yourself. Dacor is not responsible for service required to correct a faulty installation.

Installation Checklist

warning

To ensure a safe and proper installation, the follow- ing checklist should be completed by the installer to ensure that no part of the installation has been over- looked.

Proper installation is the responsibility of the hom- eowner. The importance of proper installation of your Dacor range hood cannot be overemphasized.

□□Is the hood properly attached to the wall according to the instructions on page 16 and 17?

□□Is the duct work completely installed? Are all joints attached with sheet metal screws and wrapped with duct tape? See page 18.

□□Is the range hood wired and grounded according to these instructions and in accordance with all applicable electric codes? See page 18.

□□Are the filters properly installed according to the use and care manual?

□□Has proper operation been verified?

□□Have any problems been noted on the warranty card or during the on-line warranty activation? Has the warranty been activated on-line or the warranty card filled out completely and mailed?

21