INSTALLATION

BUILT–IN CONSTRUCTION DETAILS

13-3/4"

Bottom of support flange

2"

22"

 

 

25-1/2"

grill

exhaust

3" (to non-combustible construction / minimum lid clearance)

12" (to combustible construction)

10"

1-1/2"

Standard layoutfor non-combustible enclosure:

Layout for insulated jacket only - combustible enclosure:

10 in.2 Min. ventilation

on the back side

10in.2 min. ventilation left hand side

48" Models = 45-3/4" 36" Models = 34-1/2"

18-1/2"

NOTE: If using a backguard apron or rear wall, locate electrical serviceon the right hand side for rotisserie motor connection

3" Min. for Lid Clearance

22-3/4"

4" x 4" opening for gas supply line

10 in.2 min. ventilation

on the back side

10in.2 min. ventilation left hand

side

48" Models = 51-5/8" 36" Models = 40-1/2"

18-1/2"

NOTE: If using a backguard apron or rear wall, locate electrical service on the righthandside for rotisserie motor connection

3" Min. for Lid Clearance

23-3/4"

4" x 4" opening for gas supply line

3"

10-1/8"

35-1/2" Max.

1" Min.

 

10 in.2 min.

 

ventilation

20"

on the right

hand side

 

 

opening for access doors/

48" Models = 46"

drawers

(see Fig. 06 & 07 for

36" Models = 34"

orderinginformation)

11-1/8"

35-1/2"

Max. 1" Min.

20"

48" Models = 46" 36" Models = 34"

10 in.2 min. ventilation on the right handside

opening for access doors/drawers (see Fig. 06 & 07 for ordering information)

WARNING!

If installing the grill into a non-combustible enclosure,all combustible construction muststill be outsidethe 12 inch clearance zone.If your island is madeof stucco overthe top of wooden studs,the wood can not be inside the 12 inch clearance zone to combustible,even though the stucco is what is touching the grillarea.

INSULATED JACKET

Size

Part No.

3670167

4870172

FIG. 05

10

Page 12
Image 12
DCS BGB Series manual BUILT-IN Construction Details