12
GAS REQUIREMENTS
Verify the type of gas supply to be used, either natural or LP, and make sure the marking on the appliance rating
plate agrees with that of the supply. The rating plate is located underneath the unit bottom. Never connect an
unregulated gas line to the appliance. You must use the gas regulator provided with the unit, even if the supply
is controlled.
An installer-supplied gas shut-off valve must be installed in an easily accessible location. All installer supplied
parts must conform to local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA
70 or the Canadian Electrical Code, CSA C22.1, and the National Fuel Gas Code, ANSI Z223.1 or CAN/CGA-B149.1
Natural Gas Installation Code or CAN/CGA-B149.2 Propane Installation Code.
All pipe sealants must be an approved type and resistant to the actions of LP gases. Never use pipe sealant on
flare fittings. All gas connections should be made by a qualified technician and in accordance with local codes
and ordinances. In the absence of local codes, the installation must comply with the National Fuel Gas Code
ANSI Z223.1. Gas conversion kits are available from the factory. When ordering gas conversion kits, have the
model number, and the type of gas (natural or LP) from your grill.
TOTAL GAS CONSUMPTION OF THE GRILL WITH ALL BURNERS ON HI:
BGB48-BQR - 126,500 Btu/hr BGB48-BQAR - 121,500 Btu/hr BGB36-BQAR - 92,500 Btu/hr
The applianceand its individual shut-off valve must be disconnected from the gas supply piping system during
anypressure testing of thatsystem at test pressures in excess of 1/2 PSIG (3.5 kPa.) The appliance must be
isolated from the gas supply piping system byclosing its individual manual shut-off valve during any pressure
testing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG (3.5 kPa.). The installation
of this appliancemust conformwith local codes or,in the absenceof local codes,with the National Fuel Gas
Code,ANSI Z223.1. Installation in Canada must be in accordance with the Standard Can1-b149.1 and/or .2
(installation code for gas burning appliances and
equipment) and local codes.
NATURAL GAS HOOK UP: (THIS TYPE OF CON-
NECTION SHOULD BE PERFORMED BY A CERTIFIED OR
LICENSED TECHNICIAN ONLY.)
Connection: 1/2" NPT male with 3/8" flare adapter.
Operating pressure: 4.0" W.C. Supply pressure: 5" to 14"
water column. If in excess of 14" W.C., a step down
regulator is required. Check with your local gas utility
company or local codes for instructions on installing gas
supply lines. Be sure to check on type and size of run,
and how deep to bury the line. If the gas line is too small,
the grill will not function properly. Any joint sealant used
must be an approved type and be resistive to the actions
of LP gases.
TOHOOK-UP THE FITTINGS SUPPLIED WITHTHE GRILL:
Assemble as shown (Fig. 08). Use threading compound on
male threads only. Do not use threading compound on
the male end of the 1/2 NPT to 3/8 flare adapter. Use a
second pipe wrench to hold the grill inlet pipe to avoid
shifting any internal gas lines of the grill. Ensure that the
regulator arrow points in the direction of gas flow towards
the unit, away from the supply. Do not forget to place the installer-supplied gas valve in an accessible location.
LP GAS HOOK UP (TY PE 1 OR QCC1 REGULATOR):
Grills orificed for use with LP gas come equipped with a high capacity hose/regulator assembly for connection to
astandard20 lb.LP cylinder (Type 1). The LP tank is not included.
*Installationmust conform with
localcodes or with the National
FuelGas Code ANSI Z223.1 or
theCAN/CGA-B149.2 Propane
InstallationCode
Coupling
1/2”NPT x
2.0”
NIpple
Regulator
4.0"W.C.
Adapter1/2” NPT
to3/8” flare fitting
Donot put threading
compoundon these
threads
Bottomof unit
Threadingcompound
mustbe resistant to LP gas
1/2”NPT x 5.0"
Nipple
Installersupplied shut-off
valvemust be easily
accessible*
FIG. 08 Natural Gas
INSTALLATION
GAS HOOK-UP