INSTALLATION

GAS HOOK-UP

Connection: 1/2" NPT male with a 3/8" Flare adapter (included). LP Hose with a quick disconnect and fittings are

included. Operating pressure: 11.0" W.C.

CAUTION!

Before connecting LP tank to regulator, check that all grill burners and side burners, smokers, and rotisserie valves are in the OFF position and open grill lid.

To connect the LP regulator/hose assembly to the tank/valve assembly, first make sure the main valve on the tank is completely closed. Although the flow of gas is stopped when the Type 1 system is disconnected as part of of its safety feature, you should always turn off the LP tank main valve (Fig. 09) after each use and during transport of the tank or unit. Insert the regulator inlet into the tank valve and turn to the black coupler clockwise until the coupler tightens up. Do not overtighten the coupler. Turn the main tank valve on and turn the burner control valves on the unit to the “HI” position for about 20 seconds to allow the air in the system to purge, turn valves off and wait 5 minutes before attempting to light the burners.

To disconnect the coupler, first make sure the main tank valve is turned off. Grasp the coupler and turn counter clockwise. The inlet will then disengage. Remove the inlet from the tank valve opening if it has not already done so when it disengaged. Your local LP filling station should be equipped with the proper equipment to fill your tank.

LP TANK REQUIREMENTS:

A dented or rusty LP tank may be hazardous and should be checked by your LP supplier. The cylinder that is used must have a collar to protect the cylinder valve. Never use a cylinder with a damaged valve. Always check for leaks after every LP tank change. The LP gas cylinder must be constructed and marked in accordance with the specifications for LP gas cylinders of the U.S. Department of Transportation (DOT or CAN/CSA-B339) and designed for use with a Type 1 system only. Do not change the regulator/hose assembly from that supplied with the unit or attempt to use a Type 1 equipped regulator/hose assembly with a standard 510 POL tank/valve assembly. The cylinder must be provided with a shut-off valve terminating in an LP gas supply cylinder valve outlet specified, as applicable, for connection Type 1. If the appliance is stored indoors, the cylinder must be disconnected and removed from the appliance. Cylinders must be stored outdoors in a well-ventilated area out of the reach of children.

Note:

When an LP unit is being directly connected to an LP house system, you must follow the natural gas hook up guidelines. The installer must provide the proper gas regulator to reduce the gas flow to 11” W.C.

Note:

The Grill comes with the LP Regulator/Hose assembly installed at the factory. The assembly, along with the entire Grill system, is leak tested. Do not remove the Regulator/Hose

assembly from the Grill during installation.

 

WARNING :

 

Bottom of unit

1.

Do not remove the Grill from the pallet until you are

 

 

 

 

ready to install.

Type 1 Regulator

 

2.

Do not place the Grill directly on the ground or any other

Main Tank Valve

Elbow 45º

1/2” female

 

flat surface without support. This will prevent damaging

 

NPT x 3/8” male flare

 

 

(installed on the unit)

 

the regulator/hose assembly by the weight of the grill.

 

 

3.

Check the hose, regulator and connectors for damage.

 

LP Regulator hose

 

assembly 11" W.C.

 

Look for cracks, abrasions, brittleness, holes, dents and

20 lb. LP Tank

*Installation must conform with

 

nicks.

 

 

 

local codes or with the National

 

 

 

Fuel Gas Code ANSI Z223.1 or the

4.

Do not attempt to remove, repair, or replace the

 

CAN/CGA-B149.2 Propane

 

Installation Code

Regulator/Hose assembly by yourself. It must be done

FIG. 09 LP Gas

by a qualified licensed technician only.

 

13

Page 15
Image 15
DCS BGB48-BQAR, BGB48-BQR manual LP Tank Requirements, LP Gas

BGB48-BQAR, BGB48-BQR specifications

The DCS BGB48-BQR and BGB48-BQAR are cutting-edge battery systems designed for a range of applications, primarily focusing on delivering reliable energy storage solutions. These models are part of a contemporary line of products that exemplify advanced technologies in battery management and energy efficiency.

One of the key features of the BGB48-BQR and BGB48-BQAR is their high energy density, which maximizes the usable energy within a compact form factor. This is particularly beneficial for applications that require a substantial amount of energy but have limited space for battery installation. The sleek design not only enhances the aesthetics of installations but also allows for flexible integration into existing systems.

The technology utilized in these batteries includes lithium-ion cells, which are renowned for their longevity and performance. With a cycle life that often surpasses 3,000 cycles, users can expect these batteries to maintain their capacity over extended periods, reducing the need for frequent replacements. This durability translates into lower operational costs and less environmental impact.

Another standout characteristic is the sophisticated Battery Management System (BMS) integrated into both models. The BMS continuously monitors the health of each battery cell, ensuring optimal performance and safety. It balances charging and discharging processes, mitigates risks of overcharging or overheating, and extends the overall lifespan of the battery. Additionally, the BMS provides real-time data to users, facilitating informed decision-making regarding energy consumption and battery usage.

Safety is a paramount consideration in the design of the DCS BGB48-BQR and BGB48-BQAR systems. These batteries incorporate multiple layers of protection, including thermal management that prevents overheating, as well as protective circuits that safeguard against short circuits and electrical surges.

Furthermore, both models support various communication protocols, enabling seamless integration with smart energy systems. This feature allows them to interact with solar panels, inverters, and grid systems, making them suitable for renewable energy applications and storage.

In summary, the DCS BGB48-BQR and BGB48-BQAR represent the forefront of battery technology with their high energy density, advanced BMS, robust safety features, and adaptability for a diverse range of applications. These characteristics make them an ideal choice for businesses and individuals seeking efficient, reliable, and sustainable energy storage solutions.