Table 6-5. Environmental Requirements
Specification | Operational | Nonoperational |
|
|
|
|
|
Airflow requirements | Internal: 6 CFM (front to back) | N/A |
|
|
|
|
|
Altitude |
| ||
|
|
|
|
Humidity gradient | 10% per hour | 10% per hour |
|
|
|
|
|
Relative humidity | 20% to 80% | 5% to 95% |
|
|
|
|
|
Shock (1/2 sine wave) | 31G +/- 5%, 2.6 ms | 71G +/- 5%, 2.0 ms |
|
Temperature | +50° to +140° F |
| |
| (+10° to + 60° C) |
| |
|
|
|
|
Thermal gradient | 10° C per hour over temp. range | 20° C per hour over temp. range |
|
|
|
|
|
Vibration (sweep test) | 0.005 inches DA | 0.1 inches |
|
| 0.50 G peak | 1.0 G |
|
|
| 1.0 octave per minute |
|
|
|
|
|
|
|
|
|
Injected Noise Specifications
The
Reliability Specifications
The PowerVault
Table 6-6. Reliability Specifications
Specification | Description | |
|
| |
Cartridge load/eject | 100,000 cartridge load/eject cycles (no thread) | |
|
|
|
Error recovery and control | • | Error correction code techniques |
|
| (C1 and C2 ECC) |
| • | |
| • | Error monitoring and reporting (error log) |
| • | Retry on |
|
| |
Mean time between failures (MTBF)at 100% duty cycle with power applied and tape moving | 250,000 hours | |
continuously |
|
|
|
| |
Mean time to replace (MTTR) | Less than 30 minutes | |
Nonrecoverable error rate | Less than 1 in 101 7 bits |
Mean Time Between Failures
The mean time between failures (MTBF) is specified at 250,000 hours minimum. This specification includes all
NOTE: The MTBF rating does not represent any particular drive, but is derived from a large database of test samples. Actual rates may vary from unit to unit.
Mean Time to Replace
The mean time to replace (MTTR) is the average time required by a qualified service technician to diagnose a defective drive and to install a replacement drive. The MTTR for LTO products is less than 0.5 hour (30 minutes).
The LTO drives are