Port Number

Protocols

Port Type

Max.

Direction

Usage

Configurable

 

 

 

Encryption

 

 

 

 

 

 

Level

 

 

 

 

 

 

 

 

 

 

443

HTTPS

TCP

128–bit

In

HTTPS server

No

8080

HTTP

TCP

 

In

HTTP server;

No

 

 

 

 

 

downloads the

 

 

 

 

 

 

OMSA VIB and

 

 

 

 

 

 

fixes non-

 

 

 

 

 

 

compliant

 

 

 

 

 

 

vSphere hosts

 

50

RMCP

UDP/TCP

128–bit

Out

Remote Mail

No

 

 

 

 

 

Check Protocol

 

51

IMP

UDP/TCP

N/A

N/A

IMP Logical

No

 

 

 

 

 

Address

 

 

 

 

 

 

Maintenance

 

5353

mDNS

UDP/TCP

 

All

Multicast DNS

No

631

IPP

UDP/TCP

None

Out

Internet

No

 

 

 

 

 

Printing

 

 

 

 

 

 

Protocol (IPP)

 

69

TFTP

UDP

128–bit

All

Trivial File

No

 

 

 

 

 

Transfer

 

111

NFS

UDP/TCP

128–bit

In

SUN Remote

No

 

 

 

 

 

Procedure Call

 

 

 

 

 

 

(Portmap)

 

68

BOOTP

UDP

None

Out

Bootstrap

No

 

 

 

 

 

Protocol Client

 

What are the Minimum requirements for successful installation and operation of the virtual appliance?

The following settings outline the minimum appliance requirements:

Physical RAM: 3 GB.

Reserved Memory: 1 GB

NOTE: For optimal performance Dell recommends 3 GB.

Disk: 32.5 GB.

CPU: 2 virtual CPUs.

Why is the password not changed for the user used for bare-metal discovery after successfully applying the hardware profile that has the same user with new changed credentials in the iDRAC user list?

The password of the user used from discovery is not changed to the new credential if only hardware profile template is selected for deployment. This is done intentionally so that the plugin is able to communicate with the iDRAC future use in deployment needs.