8

Virtualization-related Events For Dell PowerEdge Servers

The following table contains virtualization-related critical and warning events, including event name, description and severity level for 11th, 12th, and 13th generation of PowerEdge servers.

Table 5. Virtualization-related Events of 11th, 12th, and 13th Generation PowerEdge Servers

Event Name

Description

Severity

Recommended Action

Dell-Current sensor

A current sensor in the

Warning

No action

detected a warning value

specified system exceeded

 

 

 

its warning threshold.

 

 

Dell-Current sensor

A current sensor in the

Error

Put the system into

detected a failure value

specified system exceeded

 

maintenance mode

 

its failure threshold.

 

 

Dell-Current sensor detected a non-recoverable value

A current sensor in the

Error

No action

specified system detected

 

 

an error from which it

 

 

cannot recover

 

 

Dell-Redundancy regained

Sensor Returned to Normal

Info

No action

 

Value

 

 

Dell-Redundancy degraded

A redundancy sensor in the

Warning

No action

 

specified system detected

 

 

 

that one of the components

 

 

 

of the redundancy unit has

 

 

 

failed but the unit is still

 

 

 

redundant.

 

 

Dell - Redundancy lost

A redundancy sensor in the

Error

Put the system into

 

specified system detected

 

maintenance mode

 

that one of the components

 

 

 

in the redundant unit has

 

 

 

been disconnected, has

 

 

 

failed, or is not present.

 

 

Dell - Power supply

Sensor Returned to Normal

Info

No action

returned to normal

Value

 

 

Dell - Power supply

A power supply sensor

Warning

No action

detected a warning

reading in the specified

 

 

 

system exceeded a user

 

 

 

definable warning

 

 

 

threshold.

 

 

93

Page 93
Image 93
Dell 2.3 manual Virtualization-related Events For Dell PowerEdge Servers, Event Name Description Severity