324 Viewing Statistics
www.dell.com | support.dell.com
New Alarm Entry
3Define the New Alarm Index, Sample Variable, Sample Type, Rising Threshold,
Rising Event, Falling Threshold, Falling Event, Startup Alarm, Interval, and Owner
fields.
4Click Apply Changes. The RMON alarm is added, and the device is updated.
Modifying an Alarm Table entry:
1Open the RMON Alarm page.
2Select an RMON Alarm Table entry in the Alarm Entry drop-down box.
3Modify the Sample Type, Rising Threshold, Rising Event, Falling Threshold, Falling
Event, Startup Alarm, Interval, and/or Owner fields.
4Click Apply Changes. The RMON Alarm Table entry is modified, and the device is
updated.
Displaying the Alarm Table:
1Open the RMON Alarm Table.
2Click Show All. The RMON Alarm Table opens.