&RPSXWHU6HUYLFH
The following subsections provide
6\VWHP3RZHU6XSSO\
The
NOTE:9ROWDJHThe power supply5DQJHproduces DC voltages only under0D[LPXP&XUUHQWits loaded2XWSXWcondi- tion. Therefore, when you measure these voltages, the DC power connectors must be connected to their corresponding power input connectors on the sys- tem board or drives.
.
+3.3 VDC | +3.15 to +3.45 VDC | 18.0 A |
+5 VDC | +4.75 to +5.25 VDC | 35.0 A |
+12 VDC | +11.40 to +12.60 VDC | 14.0 A |
0.3 A | ||
0.3 A | ||
+5 VFP2 | +4.75 to +5.25 VDC | 1.2 A |
1Maximum continuous DC output power should not exceed 330 W. Maximum combined load on +5 VDC and +3.3 VDC cannot exceed 200 W.
2VFP (volts flea power) — sometimes called “standby power.”
3LQ$VVLJQPHQWVIRUWKH'&3RZHU&RQQHFWRUV
The
System Overview |