Local Members

Status

Local Members

Status

-----------------

------

-----------------

------

Gi1/0/14

Up

Gi1/0/13

Up

Peer Members

Status

Peer Members

Status

----------------

------

----------------

------

Gi1/0/13

Up

< * run command from Primary for this information >

Note: Running the show vpc brief command on the primary shows the complete status of both peer switches. Running the show vpc brief command on the secondary shows status of the secondary only.

Results of the command should be the same as shown above. All member ports must show “UP”, and the “VPC interface state” must show “Active”. The show interface port-channelis another helpful tool to let you know if the configured LAGs are up and running. This command must also only be run on the primary peer when used in a two-tier topology. If correctly configured, ports in the primary LAG are listed with an “Active” status. Inactive ports are usually a sign of a cabling or configuration issue.

MLAG Primary Peers only: B and D

show interface port-channel 40

Channel PortsCh-Type Hash Type Min-links Local Prf

------- ----------------------------- -------- --------- --------- ----

Po40 Active: Gi1/0/1, Gi1/0/2 Dynamic 7

1

Disabled

Hash Algorithm Type

1 - Source MAC, VLAN, EtherType, source module and port Id

2 - Destination MAC, VLAN, EtherType, source module and port Id 3 - Source IP and source TCP/UDP port

4 - Destination IP and destination TCP/UDP port

5 - Source/Destination MAC, VLAN, EtherType, source MODID/port

6 - Source/Destination IP and source/destination TCP/UDP port

7 - Enhanced hashing mode

Like the show vpc brief command, the show interfaces port-channel command must be run from the primary peer to receive information from both of the peer switches.

18 Using MLAG in Dell Networks

.

Page 18
Image 18