Delta 36-812, 34-814, 34-806, 34-801 Adjusting Table Insert, Miter Gage Operation And Adjustment

Models: 34-801 34-806 34-814 36-812

1 28
Download 28 pages 38.89 Kb
Page 16
Image 16
ADJUSTING TABLE INSERT

ADJUSTING TABLE INSERT

Place a straight edge (B) across the table at both ends of the table insert as shown in Fig. 46. The table insert (A) should always be level with the table. If an adjustment is necessary, turn the adjusting screws (C), as needed, with allen wrench supplied. NOTE: THE MITER GAGE

HANDLE CAN BE USED TO STORE THE ALLEN WRENCHES WHEN NOT IN USE. REMOVE THE TOP CAP OF THE MITER GAGE HANDLE FOR THE ALLEN WRENCH STORAGE COMPARTMENT.

MITER GAGE OPERATION AND ADJUSTMENT

Insert the miter gage bar into the miter gage slot and assemble the washer and lock handle (A) Fig. 47, to the miter gage bar as shown.

The miter gage is equipped with adjustable index stops at 90 degrees and 45 degrees right and left. Adjustment to the index stops can be made by tightening or loosening the three adjusting screws (B) Fig. 48, with allen wrench supplied.

To rotate the miter gage, loosen lock knob (A) Fig. 48, and move the body of the miter gage (C), to the desired angle.

The miter gage body will stop at 90 degrees and 45 degrees both right and left. To rotate the miter gage body past these points, the stop link (D) Fig. 48, must be moved up and out of the way.

The head of the miter gage pivots on a special tapered screw (G) that fastens the head to the miter gage bar. If the miter gage head does not pivot freely, or pivots too freely, it can be adjusted by loosening set screw (H) Fig. 49, and turning the screw (G) in or out. Be certain to tighten screw (H) after adjustment is made. Your miter gage is equipped with a plate (E) Fig. 49, which fits into the T-Slot groove in the table. This allows the miter gage to be pulled off the front edge of the table without falling. This allows for a longer cut off capacity in front of the blade.

C A B

C

Fig. 46

A

Fig. 47

AMITER GAGE OPERATION AND ADJUSTMENT

CC A B

Manual backgroundB

BManual background D

Fig. 48

Fig. 49

16

Page 16
Image 16
Delta 36-812, 34-814 Adjusting Table Insert, Miter Gage Operation And Adjustment, C A B C Fig. A Fig. A C B BD Fig. Fig