Delta 34-814 Five Horsepower Motors, Three Phase Operation, Magnetic Push Button Controls, Fig. D

Models: 34-801 34-806 34-814 36-812

1 28
Download 28 pages 38.89 Kb
Page 5
Image 5
FIVE HORSEPOWER MOTORS

FIVE HORSEPOWER MOTORS

The motors supplied with single phase, 5 horsepower Unisaws are designed to be operated from a 220-240 volt power system.

The 5 horsepower Unisaws are not supplied with a power cord. They must be permanently connected to the building electrical system and grounded according to the National Electrical Code. Since they are permanently connected to the building electrical system, extension cords cannot be used with the 5 horsepower Unisaw.

THREE PHASE OPERATION

Three phase Unisaws are not supplied with a power cord. They must be permanently connected to the building electrical system and grounded according to the National Electrical Code. Since they must be permanently connected to the building electrical system, extension cords cannot be used with three phase Unisaws.

MAGNETIC PUSH BUTTON CONTROLS

If you purchased the Unisaw with a magnetic starter, transformer and overload protection (LVC), refer to the separate electrical instruction manual supplied with the machine.

EXTENSION CORDS

Use proper extension cords. Make sure your extension cord is in good condition and is a 3-wire extension cord which has a 3-prong grounding type plug and matching receptacle which will accept the machine’s plug. When using an extension cord, be sure to use one heavy enough to carry the current of the machine. An undersized cord will cause a drop in line voltage, resulting in loss of power and overheating. Fig. D, shows the correct gauge to use depending on the cord length. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.

MINIMUM GAUGE EXTENSION CORD

RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES

Ampere

 

Total Length

Gauge of

Rating

Volts

of Cord in Feet

Extension Cord

0-6

240

up to 50

18 AWG

0-6

240

50-100

16 AWG

0-6

240

100-200

16 AWG

0-6

240

200-300

14 AWG

6-10

240

up to 50

18 AWG

6-10

240

50-100

16 AWG

6-10

240

100-200

14 AWG

6-10

240

200-300

12 AWG

 

 

 

 

10-12

240

up to 50

16 AWG

10-12

240

50-100

16 AWG

10-12

240

100-200

14 AWG

10-12

240

200-300

12 AWG

 

 

 

 

12-16

240

up to 50

14 AWG

12-16

240

50-100

12 AWG

12-16

240

GREATER THAN 100 FEET NOT RECOMMENDED

 

 

 

 

Fig. D

5

Page 5
Image 5
Delta 34-814, 36-812 Five Horsepower Motors, Three Phase Operation, Magnetic Push Button Controls, Extension Cords, Fig. D