Delta R18448, R18224 instruction sheet 2 R18222 & R18222-WS, R18222 & R18222-WS Installation

Models: R18448 R18224

1 36
Download 36 pages 45.67 Kb
Page 7
Image 7
2R18222 & R18222-WS

2R18222 & R18222-WS

5

3 Port, 6 Function

Installation

7

R18222 & R18222-WS Installation4

1

3

10

9

8

2

2 Port, 3 Function Installation

5

6

8

9

R18222 & R18222-WS Installation

Remove the bonnet nut, cartridge and plasterguard (1), plus, the screen, test cap, bonnet nut, plasterguard and cover

(2)before soldering. Connect valve body to water supplies using the proper fittings.

Note: (3) is the cold inlet port and (4) is the hot inlet port.

Solder a tube (5) from main outlet of the jet module to the shower arm elbow to the desired height. Determine whether a three or six function configuration is desired. For

2 port, 3 function; solder plug into auxiliary port (6) in casting. For 3 port, 6 function; all outlet ports are used. It is recommended to mount valves to stringers as shown.

If you are making a back to back or reverse installation (hot on right and cold on left)

install the valve body as described, but reverse the water supply lines.

After soldering press in the detent (7) into proper hole as shown, reinstall all other parts in reverse order; ensure bonnet nuts are tightened securely. Then install the the stops into the body; be careful not to overtighten the nuts.

Note: Install stops in the w/stops version as

follows: Thread nut (8) on stem (9) as shown. Then press stem and nut assembly into body

(10)and tighten using a 3/8", 6 point, deep well socket. With a flat head screwdriver, adjust stem clockwise to close and counterclockwise to open.

7

Page 7
Image 7
Delta R18448, R18224 instruction sheet 2 R18222 & R18222-WS, R18222 & R18222-WS Installation