Ethernet Communication Module DVPEN01-SL

CR#116: Modbus TCP Status

Explanations:

Displaying the current communication status of Modbus TCP mode. When the CR value is set as”0” Æ the data have not yet been received; when the CR value is set as “1” Æ the data exchange is in progress; when the CR value is set as “2” Æ the data exchange is successful; when the CR value is set as “3” Æ the data exchange fails.

CR value

Data exchange status

0

The data have not been received.

 

 

1

The data exchange is in progress.

 

 

2

The data exchange is successful.

 

 

3

The data exchange fails.

 

 

CR#117, 118: Modbus TCP Destination IP

Explanations:

Setting up the destination IP address in Modbus TCP mode. See explanations on CR#70 and #71 for how to set.

CR#119: Modbus TCP Data Length

Explanations:

Setting up the length of communication data in Modbus TCP mode. Length for 8-bit mode: K1

~K100; length for 16-bit mode: K1 ~ K200.

CR#120 ~ 219: Modbus TCP Data Buffer

Explanations:

Buffer for transmitted/received data in Modbus TCP mode.

CR#251: Error Code

Explanations:

Table of error code:

Bit No.

Error

b0

The network is not yet connected.

 

 

b1

Incorrect IP setting

 

 

b2

CR#13 is set as “transmitting data”, but the data exchange

is forbidden.

 

b3

CR#13 is set as “transmitting data”, but the data exchange

mode has not yet been enabled.

 

b4

NTP-Server connection fails.

 

 

b7

SMTP-Server connection fails.

 

 

b8

DHCP has not obtained the correct network parameter.

 

 