Delta Electronics manual Ethernet Communication Module DVPEN01-SL, „ Data Exchange

Models: DVPEN01-SL

1 54
Download 54 pages 48.9 Kb
Page 11
Image 11
„Data Exchange

 

 

Ethernet Communication Module DVPEN01-SL

 

 

 

 

 

CR value

E-Mail status

 

 

10

Fail to connect to SMTP-Server

 

 

 

 

 

 

11

Incorrect recipient E-Mail address

 

 

 

 

 

 

12

SMTP-Server communication error

 

 

 

 

 

 

13

Exceeding the max. number of TCP connection

 

 

 

 

 

 

3 ~ 9, 14 ~ 255

Reserved

 

 

 

 

 

CR#9 ~ 12: E-Mail 1 ~ 4 Additional Message

Explanations:

The user fills in the code, and the code will be stored in the title of the E-Mail and sent out with the E-Mail.

„Data Exchange

CR#13: Data Exchange Trigger

Explanations:

When the CR is set as “0”, the data in data exchange area will not be transmitted. When the CR is set as “1”, the data in data exchange area will be transmitted.

CR#14: Data Exchange Status

Explanations:

When the CR is set as “0”, the data have not yet been received. When the CR is set as “1”, the data exchange is in progress. When the CR is set as “2”, the data exchange is successful. When the CR is set as “3”, the data exchange fails.

CR value

Status

0

Data have not yet been received.

 

 

1

Data exchange is in progress.

 

 

2

Data exchange is successful.

 

 

3

Data exchange fails.

 

 

CR#25, 26: Destination IP

Explanations:

To set up the Slave IP address for data exchange manually, write “0” into CR#28 first before setting up the destination IP. See explanations on CR#70 and #71 for how to set.

CR#28: Destination Slave ID

Explanations:

When you set up the Salve ID (i.e. K1 ~ K255) for data exchange, DVPEN01-SL will automatically search for the corresponding IP address from the Slave IP list. For example, if the ID is set as “0”, the value in CR#25 and #26 will be regarded as the destination IP.

CR#29 ~ 48: Data Transmission Buffer

Explanations:

DVP-PLC Application Manual

9

Page 11
Image 11
Delta Electronics manual Ethernet Communication Module DVPEN01-SL, „ Data Exchange