6.7Setting up Static ARP Table

Ethernet Communication Module DVPEN01-SL

6.7Setting up Static ARP Table

Application

 

Setting up static ARP table

 

 

 

 

Network

(1)

MAC address of equipment 192.168.1.6 is 00:18:23:10:00:35

requirement

(2)

MAC address of equipment 192.168.1.1 is 00:18:23:10:00:04

 

 

 

 

1.See 6.1 for the connection and how to set up the communication.

2.Open the setup page and switch to “Static ARP Table” page.

3.Check “Enable ARP Table” box. Enter “192.168.1.6” in No. 1 IP, and its corresponding MAC address is “00:18:23:10:00:35”.

4.Enter “192.168.1.1” in No.2 IP, and its MAC address is “00:18:23:10:00:04”. Click on “OK” to complete the setting. Only the equipment within the IP range can be connected.