ENGLISH
Getting |
| Step 2 : Measurement |
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| ||
F Menu screen F |
|
|
|
|
| ||||||
Started |
|
| q |
|
|
|
|
| |||
|
|
| Auto Setup |
| w | ||||||
|
|
| Audyssey MultEQ |
|
|
|
|
|
|
| |
|
|
|
|
| Auto Setup |
| |||||
Connections |
| Step2:Measurement |
|
|
| ||||||
|
|
|
| Audyssey MultEQ |
| ||||||
|
| Next |
|
|
|
| |||||
|
|
|
| Step2:Measurement |
| ||||||
|
|
| Please place microphone |
|
|
| |||||
|
|
| at ear height at |
|
|
|
|
|
|
| |
|
|
| 2nd listening position. |
|
| Now measuring 2nd |
|
| |||
|
|
| Calculate |
|
| listening position. |
|
| |||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| ||
Setup |
|
| Cancel |
|
|
| Front L |
|
| ||
|
|
|
|
| Cancel |
| |||||
|
| e |
|
|
|
| |||||
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
| ||
Playback |
|
| Auto Setup |
|
|
|
|
| |||
|
| Audyssey MultEQ |
|
|
|
|
| ||||
|
| Step2:Measurement |
|
|
|
|
| ||||
|
|
| Please place microphone |
|
|
|
|
| |||
|
|
| at ear height at |
|
|
|
|
| |||
Remote |
|
| 3nd listening position. |
|
|
|
|
| |||
|
| Next |
|
|
|
|
| ||||
|
|
| Calculate |
|
|
|
|
| |||
Control |
|
| Retry |
|
|
|
|
| |||
|
| Cancel |
|
|
|
|
| ||||
|
|
|
|
|
|
|
| ||||
| q Press u to select “Next 0”, then press o. | ||||||||||
|
| • The measurement of the 2nd position starts. | |||||||||
w Move the microphone to the 3rd position and press o. | |||||||||||
| |||||||||||
zone |
|
| • The measurement of the 3rd position starts. | ||||||||
e Perform w repeatedly for the 4th, 5th, and 6th measurments. | |||||||||||
Information |
|
| • “All the measurements were finished.” is displayed on the on- | ||||||||
|
| screen display. When you have completed measurements in 6 | |||||||||
|
|
| |||||||||
|
|
| positions. |
|
|
|
|
| |||
|
|
| • If you want to stop after measuring just five or fewer positions, | ||||||||
Troubleshooting |
|
| press i to select “Cancel 0”, then press o. | ||||||||
surrounding positions. Although it is allowable to measure less than 6 | |||||||||||
| After completing a measurement position, move the microphone to | ||||||||||
| the next position. |
|
|
|
|
| |||||
| Measure at 6 positions: the main listening position and 5 other | ||||||||||
Specifications | positions, it is recommended to measure 6 for best results. | ||||||||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
FMenu screen F q
Auto Setup |
|
|
Audyssey MultEQ | Auto Setup | |
Step2:Measurement |
| |
| Audyssey MultEQ | |
All the measurements |
| |
Step3:Calculation |
were finished.
Calculating
Please wait...
Calculate
Retry
Cancel––––––––––––––––––––––––––––––––––––
The values obtained from the measurements are automatically analyzed and the attributes for each of the speakers in the listening area are determined.
qPress u to select “Calculate 0”, then press o.
• Analysis begins.
•Analysis takes several minutes to complete.
•The time required for this analysis depends on the number of speakers connected. The greater the number of speakers connected, the longer analysis will take.
NOTE
•Do not change the speaker connections or subwoofer volume, or speaker locations after making measurements. If changes are necessary, make the changes and use the Audyssey MultEQ auto setup once again for an updated EQ solution.
•For instance, if the location or direction of a speaker is altered, the Auto Setup should be performed again to ensure the correct EQ solution for the new room configuration.
F Menu screen F
q
Auto Setup
Audyssey MultEQ
Step4:Check
Please check the results
of the measured item.
Speaker Config.Check
Distance Check
Channel Level Check
Crossover Freq.Check
Next
When analysis is complete, check the analysis results for the following four items.
qMake your selection using ui and press ENTER.
•Presence and size of speaker “Speaker Config. Check”
•Distance of speaker from listening position “Distance Check”
•Speaker channel level “Channel Level Check”
•Crossover Frequency “Crossover Freq. Check”
wUse ui to change which speaker is displayed.
nTo switch to another analysis result item Press RETURN.
This returns you to analysis results items, so repeat step q.
nTo proceed to “Step 5 : Store”
Press u to select “Next 0”, then press o.
Distance values that are greater than the actual distance of a speaker may be accurate for speakers with
27