ENGLISH

Started Getting

Amp Assign / Multi-zone Connections and Operations

Information zone-MultiControl Remote Playback Setup Connections

The AVR-1909 is compatible with the following types of playback:

Multi-zone playback (ZONE2)

Bi-amp playback (front speakers)

NOTE

For bi-amp playback, use speakers compatible with that type of connection.

When conducting bi-amp playback, remove the short-circuiting boards (or wires) from the speaker terminals.

Multi-zone Settings with the Amp Assign Function

The amp assign function lets you assign the amplifiers for the different channels built into the AVR-1909 to the speaker outputs for the different zones.

Select the desired playback environment from among “Setting 1” to “Setting 3”, then set the corresponding “Amp Assign” mode at menu “Manual Setup” – “Option Setup” – “Amp Assign” (vpage 35). Connect the speakers as described at “Amp Assign mode setting and speakers connected to the various speaker terminals”.

Setting 1 :

FMulti-zone playback (Default Setting) 5.1-channel playback + ZONE2 stereo playback

MAIN ZONE

ZONE2

FL SW C

FR

 

 

 

Amp Assign mode:

 

SR +

Z2L

Z2R

SL 5.1ch

 

ZONE2 (Default)

 

 

Stereo

n Amp Assign mode setting and speakers connected to the various speaker terminals

Speaker terminal

FRONT

 

SURROUND

SURROUND BACK /

 

CENTER

AMP ASSIGN

 

 

 

 

 

 

 

 

 

 

 

 

Amp Assign mode

R

L

 

R

L

R

L

 

 

 

 

 

 

 

 

 

 

ZONE2

FR

FL

C

SR

SL

Z2R

Z2L

 

 

 

 

 

 

 

 

Specifications Troubleshooting

When ZONE2 power is on, the ZONE2 channel is output from speakers connected to the SURR.BACK/ AMP ASSIGN terminals.

69