Desa CDCFTN To Turn Off Gas To Appliance, Thermostat Control Operation, Manual Lighting Procedure

Models: FDCFTP

1 42
Download 42 pages 55.09 Kb
Page 20
Image 20
TO TURN OFF GAS

20

OPERATING FIREPLACE (THERMOSTAT-CONTROLLED MODELS)

Lighting Instructions (Cont.)

To Turn Gas Off To Appliance

Thermostat Control Operation

Manual Lighting Procedure

Operating Blower

OPERATING FIREPLACE

Continued

6.With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, pages 26 through 28. Also, contact a qualified service per- son or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This fire- place has a safety interlock system. Wait one (1) minute for system to reset before lighting pilot again.

8.Turn control knob counterclockwise Shutting Off Fireplace to desired heating level. The burner should light. Set control knob to any heat level between HI and LO.

Shutting Off Burners Only (pilot stays lit) CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

Thermocouple

 

 

Ignitor Electrode

Ignitor

Thermocouple

Pilot

Electrode

Pilot

Burner

 

Burner

 

 

Figure 36 - Natural Gas Pilot Figure 37 -Propane/LP Gas Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Fireplace

1.Turn control knob clockwise THERMOSTAT CONTROL to the OFF position.

2.Turn off all electric power to the appliance (if applicable) if service is to be performed.

Shutting Off Burners Only (pilot stays lit)

Turn control knob clockwise MANUAL LIGHTING to the PILOT position.

THERMOSTAT CONTROL

OPERATION

The thermostat used on this fireplace senses the room tempera- ture. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature.

The control knob can be set to any heat level between HI and LO.

Note: The thermostat sensing bulb measures the air near the fireplace cabinet. This may not always agree with room tem- perature (depending on housing construction, installation loca- tion, room size, open air temperatures, etc.). Frequent use of your fireplace will let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Lighting Instructions, begin- ning on page 19.

2.With control knob pressed in, strike match. Hold match to pilot until pilot lights.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 under Lighting Instructions, column 1.

OPERATING

BLOWER

This blower has three settings: ON, OFF, and AUTO. In the ON position, the blower will operate constantly. In the OFF posi- tion, the blower will not operate. In the AUTO position, the blower will start when the thermostat senses a sufficient in- crease in firebox temperature.

Note: Your fireplace and thermostat blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.

Note: It is safe to operate fireplace with blower turned off. However, the blower helps distribute heated air from the fireplace.

AUTO/OFF/ON Switch

Figure 38 - AUTO/OFF/ON Blower Switch

OPERATINGManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

111244-01A

Page 20
Image 20
Desa CDCFTN To Turn Off Gas To Appliance, Thermostat Control Operation, Manual Lighting Procedure, Operating Blower