ON/OFF SERIES (MODEL [C]GHRCB)

22

OPERATING FIREPLACE (REMOTE-READY MODELS)

To Turn Off Gas To Appliance

Manual Lighting Procedure

Optional Hand-held Remote Operation

OPERATING FIREPLACE

Continued

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Fireplace

1.Turn control knob clockwise OPTIONAL HAND-HELD to the OFF position.

2.If Using Optional Hand-Held Remote: Set selector switch in the OFF position to prevent draining battery.

Shutting Off Burners Only (pilot stays lit)

Selector Switch in Remote

Flame

 

Adjustment

Position (Optional Remote

Knob

Control Knob

Control)

 

OUT IN

REMOTE

 

 

OFF

 

 

ON

 

LO

Figure 42- Setting the Selector Switch, Control Knob and Flame Adjustment Knob for Remote Operation

You may shut off the burners and keep the pilot lit by doing one of the following:

1.Turn control knob clockwise THERMOSTAT SERIES (MODEL [C]GHRCTB) to the PILOT position.

2.If Using Optional Hand-Held Remote: Use remote con- trol manual OFF button.

Manual Mode WARNING: Make sure remote sensor selector switch is in the OFF position when you are away from home for long periods of time.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Lighting Instructions, page 21.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 8 and 9 under Lighting Instructions, page 21.

ON/OFF SERIES (MODEL [C]GHRCB)

Hold the control button on the hand-held remote until burner turns on. Hold the control button again until burner turns off (see Figure 43).

TO LOCK press both buttons on hand-held remote control until light stops flashing. Hand-held remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed.

TO UNLOCK press both buttons together on hand-held remote control until the light stops flashing. The hand-held remote is now unlocked.

Control Button

Turns Burners

On and Off

Figure 43 - On/Off Hand-Held Remote Control Unit (GHRCB)

OPTIONAL HAND-HELD

REMOTE OPERATION

Note: All remote control accessories must be purchased sepa- rately (see Accessories, pages 36 and 37). Follow instructions included with the remote control.

NOTICE: You must light the pilot before using the hand-held remote control unit. See Lighting Instruc- tions on page 21.

1.After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position (see Figure 42). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

IMPORTANT: Do not leave the selector switch in the RE- MOTE or ON position when the pilot is not lit. This will drain the battery.

THERMOSTAT SERIES (MODEL [C]GHRCTB)

Thehand-heldremotecanbeoperatedusingeitherthemanualmode (MANU) or thermostatic mode (AUTO) (see Figure 44, page 23). To selectFahrenheit/Centigrademodedisplay,carefullypressthe˚C/˚F mode button with the end of a paper clip or similar blunt object.

Manual Mode

1.Press the POWER and LOCK buttons together to turn on the hand-held remote control.

2.Press the MANU button to turn on the fireplace.

3.Press the POWER and LOCK buttons together to turn off the fireplace.

Auto (Thermostatic) Mode

1.Press the POWER and LOCK buttons together to turn on the hand-held remote control.

2.Press AUTO button to select this mode.

3.Set the desired room temperature by pressing the TEMP + or - buttons.

4.Press the POWER and LOCK buttons together to turn off the fireplace

Auto (Thermostatic) ModeManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background